Resources

Case Study – Early Induction Motor Stator Fault Detection with the e-MCM

Electric motor with exposed copper stator windings, rotor shaft, and bearing inside a blue housing

Background

This short case study shows how the e-MCM sensorless condition monitoring system provides early warnings to support planned maintenance for critical motors. Understand how the e-MCM detects a developing induction motor stator issue early through the motor’s electrical signals, thus enabling the field maintenance team to perform a targeted investigation and organise timely maintenance intervention.

The e-MCM system was installed at an industrial facility and is being ulitised to monitored a critical 3.8 MW, 10 kV induction motor. The system measured the motor’s voltage and current signals during routine operation, comparing its electrical behaviour against a learned motor model to identify developing changes.

Detection & Inspection Findings

The e-MCM stator condition trend for an induction motor, showing a sustained rise above the alarm threshold
e-MCM stator indicator trend showing a sustained rise above the configured alarm threshold.

During monitoring, the stator condition indicator in the e-MCM rose above the configured alarm threshold. A stator-related summary alarm was subsequently raised by the e-MCM, prompting the field maintenance team to perform a targeted investigation into the motor’s stator condition.

The alarm recommended that the field team investigate the following issues:

These indications guided the scope of the field team’s investigation.

Induction motor stator inspection showing localised darkening and surface changes associated with early insulation deterioration
Resulting stator inspection showed localized heat effects and surface changes.

Upon deeper inspection performed by the team, they identified localised thermal effects and surface changes, which they associated with early insulation deterioration. These physical findings supported the concern raised by the e-MCM system.

Maintenance Action & Outcome

Following the warning and inspection, the field team withdrew the motor for a planned intervention, with the aim of reducing the risk of an unplanned stop and further damage.

The e-MCM connects a developing warning with a targeted inspection, enabling the maintenance team to make more informed maintenance decision. Speak with our reliability specialist to explore more on how the e-MCM sensorless system monitors motor electrical signals to detect developing issues early in your machinery asset.